Sample Record

Owner Lab

  • Granite Construction Company - Coastal

DIME Sample ID 2023-05-12-41

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/12/2023 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/12/2023
Sample typeAggregate Prequalification Program A brief description of the samplewashed sand
The quantity of what the sample constitutes2 bags of fines From where was the sample collectedSource
First name of sampler or witnessed byDylan Last name of sampler or witnessed byEvans
Title of samplerQC Technician Telephone number of sampler
Laboratory sample identification1645348140 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Felton Quarry Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-44-0003
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile sample
Where the material sample would have been placed if not sampledUse in Felton Hot Plant Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-05-12-41-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesGwynn Neilson, Granite Construction Company - Coastal08/31/2023Steve Derpich
Yes
09/05/2023
2023-05-12-41-2CTM 217-June 2011: Method of Test for Sand EquivalentGwynn Neilson, Granite Construction Company - Coastal08/31/2023Steve Derpich
Yes
09/05/2023
2023-05-12-41-3CTM 229-June 2011: Method of Test for Durability IndexGwynn Neilson, Granite Construction Company - Coastal08/31/2023Steve Derpich
Yes
09/05/2023
2023-05-12-41-4CTM 213-December 2012: Method of Test for Organic Impurities in Concrete SandNicholas Shelly, Granite Construction Company - Coastal08/21/2023Steve Derpich
Yes
09/05/2023
2023-05-12-41-5CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium SulfateNicholas Shelly, Granite Construction Company - Coastal08/22/2023Steve Derpich
Yes
09/05/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-05-12-41-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2023-05-12-41-2 CTM 217-June 2011 (Verified)
DIME Test ID: 2023-05-12-41-3 CTM 229-June 2011 (Verified)
DIME Test ID: 2023-05-12-41-4 CTM 213-December 2012 (Verified)
DIME Test ID: 2023-05-12-41-5 CTM 214-August 2010 (Verified)