Sample Record
Owner Labs
- CT HQ - Sacramento Materials Management Branch Field Office
- CT HQ - Sacramento Concrete Testing Laboratory
- CT SC - 3674 - Livermore
DIME Sample ID 2023-05-12-4
Project Information
Project Identifiers | Project ID: 99999 DEA: 0322222 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 05/12/2023 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/12/2023 |
Sample type | Quality Assurance | A brief description of the sample | structural concrete |
The quantity of what the sample constitutes | 250cy | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Brett | Last name of sampler or witnessed by | Soldano |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Materials Vernalis | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 55-0123 | |
Structure name | Test Overhead |
Material Information
Material Type | Concrete | The concrete mix design number | 123456 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 123654789 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2023-05-12-4-1 | THIS TEST HAS BEEN SUPERSEDED. ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete | Brett Soldano, CT HQ - Sacramento Materials Management Branch Field Office | 05/12/2023 | Brett Soldano | Yes | 05/24/2023 | THIS TEST HAS BEEN SUPERSEDED. | |
2023-05-12-4-2 | CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method | Brett Soldano, CT HQ - Sacramento Materials Management Branch Field Office | 05/12/2023 | Brett Soldano | No | Info | ||
2023-05-12-4-3 | ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete | Brett Soldano, CT HQ - Sacramento Materials Management Branch Field Office | 05/12/2023 | Brett Soldano | No | Info | ||
2023-05-12-4-7 | ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete | Brett Soldano, CT HQ - Sacramento Materials Management Branch Field Office | 05/12/2023 | Michael Maksimovich | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2023-05-12-4-1 ASTM C143-20 (Verified)
DIME Test ID: 2023-05-12-4-2 CTM 504-June 2010
DIME Test ID: 2023-05-12-4-3 ASTM C1064-17
DIME Test ID: 2023-05-12-4-7 ASTM C143-20