Sample Record
Owner Labs
- CT D04 - San Jose Construction Field Laboratory
- CT HQ - Sacramento Aggregate Testing Laboratory
DIME Sample ID 2023-01-19-57
Project Information
Project Identifiers | Project ID: 214986 DEA: 041J9704 EFIS: 0414000404 |
---|---|
DIST-CO-RTE-PM | 04-SCL-17-2.8/13.94 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | PAVING WITH RHMA, COLD PLANE AC, AND INSTALL CULVERT. |
Location Description | SANTA CLARA COUNTY IN AND NEAR LOS GATOS, CAMPBELL AND SAN JOSE FROM HEBARD ROAD TO ROUTE 17/280 SEPARATION |
QA Service Level | 1 (Verified on 10/19/2020) |
Sample Information
Sample Taken Date | 01/19/2023 | Sample Unique Key | 57 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/19/2023 |
Sample type | Annual Source Testing | A brief description of the sample | 1" x #4, 3/8" x #8, Sand |
The quantity of what the sample constitutes | 22 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | FERNANDO | Last name of sampler or witnessed by | VEGA |
Title of sampler | Materials Research Engineering Associate Specialist | Telephone number of sampler | |
Laboratory sample identification | SJ-012023-PCC | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Los Banos TRP (Vulcan) | Transportation Laboratory (TL) Number | C927701 C927702 C927703 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-24-0009 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2023-01-19-57-1 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | Fernando Vega, CT D04 - San Jose Construction Field Laboratory | 01/20/2023 | Fernando Vega | No | Info | ||
2023-01-19-57-2 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | Fernando Vega, CT D04 - San Jose Construction Field Laboratory | 01/20/2023 | Fernando Vega | No | Info | ||
2023-01-19-57-3 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | Fernando Vega, CT D04 - San Jose Construction Field Laboratory | 01/20/2023 | Fernando Vega | No | Info | ||
2023-01-19-57-4 | CTM 217-June 2011: Method of Test for Sand Equivalent | Fernando Vega, CT D04 - San Jose Construction Field Laboratory | 01/20/2023 | Fernando Vega | No | Info | ||
2023-01-19-57-5 | CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness) | Fernando Vega, CT D04 - San Jose Construction Field Laboratory | 01/20/2023 | Fernando Vega | No | Info | ||
2023-01-19-57-6 | CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness) | Fernando Vega, CT D04 - San Jose Construction Field Laboratory | 01/20/2023 | Fernando Vega | No | Info | ||
2023-01-19-57-7 | CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying | Fernando Vega, CT D04 - San Jose Construction Field Laboratory | 01/20/2023 | Fernando Vega | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2023-01-19-57-1 CTM 202-November 2011
DIME Test ID: 2023-01-19-57-2 CTM 202-November 2011
DIME Test ID: 2023-01-19-57-3 CTM 202-November 2011
DIME Test ID: 2023-01-19-57-4 CTM 217-June 2011
DIME Test ID: 2023-01-19-57-5 CTM 227-December 2014
DIME Test ID: 2023-01-19-57-6 CTM 227-December 2014
DIME Test ID: 2023-01-19-57-7 CTM 226-July 2010