Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2023-04-03-1

Project Information

Project IdentifiersProject ID: 993169
DEA: 050A0904
EFIS: 0513000028
DIST-CO-RTE-PM05-MON-156-R1.4/R2.0
Award Date12/14/2021
Closeout DateNot set
Work DescriptionWIDEN REINFORCED STRUCTURAL CONCRETE BRIDGE & REPLACE BRIDGE RAILING.
Location DescriptionMONTEREY COUNTY IN AND NEAR CASTROVILLE FROM 0.3 MILE EAST OF ROUTE 156/183 SEPARATION TO 0.2 MILE EAST OF CASTROVILLE BOULEVARD
QA Service Level1 (Verified on 08/17/2021)

Sample Information

Sample Taken Date04/03/2023 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testingNot set
Sample typeQuality Assurance A brief description of the sample#5 HRC 120 T-Heads
The quantity of what the sample constitutes84 From where was the sample collectedFabricator
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler2134354055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHeaded Reinforcement Corporation (HRC) Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-020-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)1201038422 Head Manufacturer Lot Number(s)100021624144
Rebar Size#5 Headed Bar Model NameHRC 120
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerNucor
Head ManufacturerNucor Utah Head FabricatorNucor
Material Standard CodeASTM A706 Headed Bar Unique ID9FW-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-04-03-1-1ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2023bewing
Yes
04/24/2023Head Popped Off
2023-04-03-1-2ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2023bewing
Yes
04/24/2023Ok Necking
2023-04-03-1-3ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2023bewing
Yes
04/24/2023Head Popped Off
2023-04-03-1-4ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/05/2023bewing
Yes
04/24/2023Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-04-03-1-1 ASTM A970-18 (Verified)
DIME Test ID: 2023-04-03-1-2 ASTM A970-18 (Verified)
DIME Test ID: 2023-04-03-1-3 ASTM A970-18 (Verified)