Sample Record

Owner Lab

  • CT D04 - Petaluma Field Laboratory

DIME Sample ID 2022-10-28-64

Project Information

Project IdentifiersProject ID: 993333
DEA: 04264724
EFIS: 0419000068
DIST-CO-RTE-PM04-MRN-101-R20.8/27.1
Award Date04/26/2022
Closeout DateNot set
Work DescriptionCIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location DescriptionMARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date10/28/2022 Sample Unique Key64
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/09/2022
Sample typeQuality Assurance A brief description of the sampleHot mix asphalt
The quantity of what the sample constitutes1 box From where was the sample collectedJob Site
First name of sampler or witnessed byCody Last name of sampler or witnessed byBrown
Title of samplerInspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDutra Richmond Transportation Laboratory (TL) Number101267
Inspector Lot Number from the Transportation Laboratory (TL) Form1 Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix NumberDO4 JMF 22 016

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-10-28-64-1THIS TEST HAS BEEN SUPERSEDED.
AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Anthony Valdez, CT D04 - Petaluma Field Laboratory11/29/2022Glenn Cea
Yes
01/31/2023THIS TEST HAS BEEN SUPERSEDED.
Tolerance = 4.9% to 5.7%
2022-10-28-64-2AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)Anthony Valdez, CT D04 - Petaluma Field Laboratory11/29/2022Glenn Cea
Yes
03/22/2023Tolerance = 4.9% to 5.7%

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-10-28-64-1 AASHTO T308-10 (Verified)
DIME Test ID: 2022-10-28-64-2 AASHTO T308-10 (Verified)