Sample Record

Owner Lab

  • Con-Fab California, LLC

DIME Sample ID 2022-09-07-102

Project Information

Project IdentifiersProject ID: 212737
DEA: 060S8304
EFIS: 0615000046
DIST-CO-RTE-PM06-FRE-5-44.4-45.4
Award Date05/26/2022
Closeout DateNot set
Work DescriptionTUMEY GULCH ABUTMENT REHAB BR# 42-0246L/R.
Location DescriptionIN FRESNO COUNTY AT TUMEY GULCH.
QA Service Level1 (Verified on 09/25/2018)

Sample Information

Sample Taken Date09/07/2022 Sample Unique Key102
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/08/2022
Sample typeQuality Control A brief description of the sample4 x 8 concrete cylinders
The quantity of what the sample constitutesGirder From where was the sample collectedManufacturer
First name of sampler or witnessed byRoberto Last name of sampler or witnessed byReyes
Title of samplerQC Technician Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCon-Fab California, LLC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameTumey Gulch Bridge

Material Information

Material TypeConcrete The concrete mix design numberSCCS980F
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2721
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of the truck Chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-09-07-102-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteRoberto Reyes Perez, Con-Fab California, LLC09/07/2022Roberto Reyes Perez
Yes
01/26/2023
2022-09-07-102-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteRoberto Reyes Perez, Con-Fab California, LLC09/07/2022Roberto Reyes Perez
Yes
01/26/2023
2022-09-07-102-3ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of ConcreteRoberto Reyes Perez, Con-Fab California, LLC09/07/2022Roberto Reyes Perez
Yes
01/26/2023
2022-09-07-102-4ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure MethodRoberto Reyes Perez, Con-Fab California, LLC09/07/2022Roberto Reyes Perez
Yes
01/26/2023
2022-09-07-102-5ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensRoberto Reyes Perez, Con-Fab California, LLC09/08/2022Roberto Reyes Perez
Yes
01/26/2023
2022-09-07-102-6ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensRoberto Reyes Perez, Con-Fab California, LLC09/15/2022Roberto Reyes Perez
Yes
01/26/2023
2022-09-07-102-7CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)Roberto Reyes Perez, Con-Fab California, LLC09/07/2022Roberto Reyes Perez
Yes
01/26/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-09-07-102-1 ASTM C1064-17 (Verified)
DIME Test ID: 2022-09-07-102-2 ASTM C143-20 (Verified)
DIME Test ID: 2022-09-07-102-3 ASTM C138-17a (Verified)
DIME Test ID: 2022-09-07-102-4 ASTM C231-17a (Verified)
DIME Test ID: 2022-09-07-102-5 ASTM C39-21 (Verified)
DIME Test ID: 2022-09-07-102-6 ASTM C39-21 (Verified)
DIME Test ID: 2022-09-07-102-7 CTM TEMP1-16 (Verified)