Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2023-01-11-3
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 208973 DEA: 120H1004 EFIS: 1200000180 COOP: 120670 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-405,73,405,605-9.3/24.3 |
| Award Date | 11/07/2016 |
| Closeout Date | Not set |
| Work Description | (Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP. |
| Location Description | Orange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2 |
| QA Service Level | 1 (Verified on 09/10/2015) |
Sample Information
| Sample Taken Date | 01/11/2023 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2023 |
| Sample type | Quality Assurance | A brief description of the sample | #10 HRC 120 T-Heads |
| The quantity of what the sample constitutes | 670 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 949-350-3970 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | HRC Fountain Valley | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-010-23 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4123151 | Head Manufacturer Lot Number(s) | 1 and 5 |
| Rebar Size | #10 | Headed Bar Model Name | HRC 120 |
| Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
| Head Shape | Square | Rebar Manufacturer | HRC |
| Head Manufacturer | HRC Fountain Valley | Head Fabricator | HRC Fountain Valley |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-04 |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-01-11-3-1 ASTM A970-18 (Verified)
DIME Test ID: 2023-01-11-3-2 ASTM A970-18 (Verified)
DIME Test ID: 2023-01-11-3-3 ASTM A970-18 (Verified)
DIME Test ID: 2023-01-11-3-4 ASTM A970-18 (Verified)
DIME Test ID: 2023-01-11-3-5 ASTM A970-18 (Verified)
DIME Test ID: 2023-01-11-3-6 ASTM A970-18 (Verified)