Sample Record

Owner Lab

  • G3 Quality, Incorporated - Cerritos

DIME Sample ID 2015-07-10-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209141
DEA: 07215954
EFIS: 0700001835
DIST-CO-RTE-PM07-LA-5-0.0/7.6
Award Date04/24/2014
Closeout Date07/14/2022
Work DescriptionWIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES
Location DescriptionLOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605
QA Service Level1 (Verified on 06/02/2014)

Sample Information

Sample Taken Date07/10/2015 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/11/2015
Sample typeQuality Control A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byDavid Last name of sampler or witnessed byIllescas
Title of samplerQC Field Technician Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namejobsite Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design number1536953
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected1
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedCIDH Pile SW 313 Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2015-07-10-8-1ASTM C1064-12: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteDavid Illescas, G3 Quality, Incorporated - Cerritos07/10/2015Brian Platt
Yes
10/23/2015
2015-07-10-8-2ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of ConcreteDavid Illescas, G3 Quality, Incorporated - Cerritos07/10/2015Brian Platt
Yes
10/23/2015
2015-07-10-8-3ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement ConcreteDavid Illescas, G3 Quality, Incorporated - Cerritos07/10/2015Brian Platt
Yes
10/23/2015
2015-07-10-8-4ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensDevin Feurtey, G3 Quality, Incorporated - Cerritos07/17/2015Brian Platt
Yes
10/23/2015

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2015-07-10-8-1 ASTM C1064-12 (Verified)
DIME Test ID: 2015-07-10-8-2 ASTM C138-17a (Verified)
DIME Test ID: 2015-07-10-8-3 ASTM C143-15a (Verified)
DIME Test ID: 2015-07-10-8-4 ASTM C39-17a (Verified)