Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2022-12-07-29

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215255
DEA: 040A7714
EFIS: 0420000287
DIST-CO-RTE-PM04-ALA-80-6.4-6.6
Award Date05/03/2021
Closeout Date12/01/2023
Work DescriptionCONSTRUCT PEDESTRIAN OVERCROSSING BRIDGE AND RETAINING WALLS. GILMAN INTERCHANGE IMPROVEMENTS
Location DescriptionALAMEDA COUNTY IN BERKELEY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.1 MILE SOUTH OF GILMAN STREET UNDERCROSSING
QA Service Level1 (Verified on 12/07/2020)

Sample Information

Sample Taken Date12/07/2022 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/08/2022
Sample typeQuality Assurance A brief description of the sample#11 Barlock Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJingan Last name of sampler or witnessed byChen
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Dayton Superior Transportation Laboratory (TL) NumberC863976
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelBarlock L Series
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)Heats MM20102405 Y3200 MM20102406 MM20105023 Rebar Heat Number(s)6032062 3113082
Rebar Size 2 Coupler Unique IDSL-17-06

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-12-07-29-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/15/2022spaine
Yes
12/20/2022Service Splice
2022-12-07-29-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/15/2022spaine
Yes
12/20/2022Service Splice
2022-12-07-29-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory12/15/2022spaine
Yes
12/20/2022Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-12-07-29-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-12-07-29-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-12-07-29-4 CTM 670-December 2013 (Verified)