Sample Record

Owner Labs

  • CT HQ - Sacramento Aggregate Testing Laboratory
  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2022-05-24-54

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/24/2022 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/13/2022
Sample typeAggregate Prequalification Program A brief description of the sampleEagle Mtn Mine Tailings - Sample No. 8
The quantity of what the sample constitutes4 full 5-gallon buckets From where was the sample collectedSource
First name of sampler or witnessed byJay Last name of sampler or witnessed byHorton
Title of samplerCaltrans Translab AMTB TET Telephone number of sampler(916) 227-1218
Laboratory sample identification7878 Linked DIME Sample ID
The fabricator/manufacturer/facility nameEagle Mtn Mine Tailings Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Eagle Mtn Mine Tailings
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedTop of Mine Tailings
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-05-24-54-15CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesRobert Jarquin, CT D08 - Fontana Southern Regional Laboratory10/12/2022Amir Behjati
Yes
11/08/2022
2022-05-24-54-16CTM 217-June 2011: Method of Test for Sand EquivalentZaid Abdelkhaliq, CT D08 - Fontana Southern Regional Laboratory10/25/2022Amir Behjati
Yes
11/08/2022
2022-05-24-54-17CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerAmir Behjati, CT D08 - Fontana Southern Regional Laboratory10/25/2022Amir Behjati
Yes
11/08/2022
2022-05-24-54-18CTM 229-June 2011: Method of Test for Durability IndexRobert Jarquin, CT D08 - Fontana Southern Regional Laboratory10/25/2022Amir Behjati
Yes
11/08/2022
2022-05-24-54-19CTM 213-December 2012: Method of Test for Organic Impurities in Concrete SandSatish Jain, CT D08 - Fontana Southern Regional Laboratory10/26/2022Amir Behjati
Yes
11/08/2022
2022-05-24-54-20CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Zaid Abdelkhaliq, CT D08 - Fontana Southern Regional Laboratory10/18/2022Amir Behjati
Yes
11/08/2022
2022-05-24-54-21CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing MachineSiegfried Mendoza, CT D08 - Fontana Southern Regional Laboratory10/25/2022Amir Behjati
Yes
11/08/2022
2022-05-24-54-22CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium SulfateSiegfried Mendoza, CT D08 - Fontana Southern Regional Laboratory10/30/2022Amir Behjati
Yes
11/08/2022
2022-05-24-54-23AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory10/27/2022Amir Behjati
Yes
11/08/2022
2022-05-24-54-24AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory10/27/2022Amir Behjati
Yes
11/08/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-05-24-54-15 CTM 202-November 2011 (Verified)
DIME Test ID: 2022-05-24-54-16 CTM 217-June 2011 (Verified)
DIME Test ID: 2022-05-24-54-17 CTM 301-March 2000 (Verified)
DIME Test ID: 2022-05-24-54-18 CTM 229-June 2011 (Verified)
DIME Test ID: 2022-05-24-54-19 CTM 213-December 2012 (Verified)
DIME Test ID: 2022-05-24-54-20 CTM 227-December 2014 (Verified)
DIME Test ID: 2022-05-24-54-21 CTM 211-May 2010 (Verified)
DIME Test ID: 2022-05-24-54-22 CTM 214-August 2010 (Verified)
DIME Test ID: 2022-05-24-54-23 AASHTO T335-09r13 (Verified)
DIME Test ID: 2022-05-24-54-24 AASHTO T304-11 (Verified)
DIME Test ID: 2022-05-24-54-25 ASTM D4791-10 (Verified)
DIME Test ID: 2022-05-24-54-26 CTM 204-June 2010 (Verified)
DIME Test ID: 2022-05-24-54-27 AASHTO T85-13 (Verified)
DIME Test ID: 2022-05-24-54-28 AASHTO T84-14 (Verified)