Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2022-07-19-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215753
DEA: 050N72U4
EFIS: 0520000169
DIST-CO-RTE-PM05-SB-101-4.4/R7.7
Award Date03/01/2021
Closeout DateNot set
Work DescriptionPlease cc Office Engineer Ni Nyoman Paul on reports sent to RE and SR. Construct High Occupancy Vehicle (HOV) lanes on U.S. Route 101 and rehabilitation - Segment 4B.
Location Description101 freeway in Summerland, CA
QA Service Level1 (Verified on 05/06/2021)

Sample Information

Sample Taken Date07/19/2022 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/22/2022
Sample typeQuality Assurance A brief description of the sample#11 Headed Reinforcements
The quantity of what the sample constitutes4 From where was the sample collectedSource
First name of sampler or witnessed byYazan Last name of sampler or witnessed byAl-Zubi
Title of sampler Telephone number of sampler
Laboratory sample identificationL160-008-22 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL160-008-22 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4118044 Head Manufacturer Lot Number(s)1
Rebar Size#11 Headed Bar Model NameHRC 120
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Rebar
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A615 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-07-19-1-1ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2022spaine
Yes
07/26/2022ok necking
2022-07-19-1-2ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2022spaine
Yes
07/26/2022ok necking
2022-07-19-1-3ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory07/25/2022spaine
Yes
07/26/2022ok necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-07-19-1-1 ASTM A970-18 (Verified)
DIME Test ID: 2022-07-19-1-2 ASTM A970-18 (Verified)