Sample Record

Owner Lab

  • RMA Group - Rancho Cordova

DIME Sample ID 2022-05-18-69

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214114
DEA: 040A5394
EFIS: 0418000244
DIST-CO-RTE-PM04-SOL-80,12-11.4/12.8, 2.1/2.8
Award DateNot set
Closeout Date02/24/2023
Work DescriptionWiden EB SR-12 Connector, Construct 3 ramps & 2 box girder bridges, remove existing bridge, etc.
Location DescriptionI-80/I-680/Route 12 Interchange
QA Service Level1 (Verified on 04/23/2019)

Sample Information

Sample Taken Date05/18/2022 Sample Unique Key69
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/18/2022
Sample typeQuality Control A brief description of the sample1x4 Aggregate
The quantity of what the sample constitutes1 Day From where was the sample collectedSupplier
First name of sampler or witnessed bySpencer Last name of sampler or witnessed byKibbe
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSyar Napa Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Syar 1110
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberCT063AC5 Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-05-18-69-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesTodd Strait, RMA Group - Rancho Cordova05/19/2022Mathew Lowrance
Yes
07/07/2022
2022-05-18-69-2CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Todd Strait, RMA Group - Rancho Cordova05/19/2022Mathew Lowrance
Yes
07/07/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-05-18-69-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2022-05-18-69-2 CTM 227-December 2014 (Verified)