Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2022-06-27-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208973
DEA: 120H1004
EFIS: 1200000180
COOP: 120670
DIST-CO-RTE-PM12-ORA-405,73,405,605-9.3/24.3
Award Date11/07/2016
Closeout DateNot set
Work Description(Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location DescriptionOrange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
QA Service Level1 (Verified on 09/10/2015)

Sample Information

Sample Taken Date06/27/2022 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/30/2022
Sample typeQuality Assurance A brief description of the sample#10 HRC 120 headed bars
The quantity of what the sample constitutes128 From where was the sample collectedFabricator
First name of sampler or witnessed byAndrew Last name of sampler or witnessed byWebster
Title of samplerQA Inspector Telephone number of sampler9254189838
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHeaded Reinforcement Corp, Fountain Valley, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL154-072-22 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4115534 Head Manufacturer Lot Number(s)1, 2
Rebar Size#10 Headed Bar Model NameHRC 120 THeads
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Steel Arizona
Head ManufacturerHRC Fountain Valley Head FabricatorHRC Fountain Valley
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-06-27-1-1ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2022spaine
Yes
07/06/2022ok necking
2022-06-27-1-2ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2022spaine
Yes
07/06/2022ok necking
2022-06-27-1-3ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2022spaine
Yes
07/06/2022ok necking
2022-06-27-1-4ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2022spaine
Yes
07/06/2022ok necking
2022-06-27-1-5ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2022spaine
Yes
07/06/2022ok necking
2022-06-27-1-6ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory07/06/2022spaine
Yes
07/06/2022ok necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-06-27-1-1 ASTM A970-18 (Verified)
DIME Test ID: 2022-06-27-1-2 ASTM A970-18 (Verified)
DIME Test ID: 2022-06-27-1-3 ASTM A970-18 (Verified)
DIME Test ID: 2022-06-27-1-4 ASTM A970-18 (Verified)
DIME Test ID: 2022-06-27-1-5 ASTM A970-18 (Verified)
DIME Test ID: 2022-06-27-1-6 ASTM A970-18 (Verified)