Sample Record

Owner Lab

  • CT D07 - Plant Services

DIME Sample ID 2022-02-25-40

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date02/25/2022 Sample Unique Key40
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing02/28/2022
Sample typeVerification A brief description of the samplePCC Agg
The quantity of what the sample constitutes150CY From where was the sample collectedDistributor
First name of sampler or witnessed byLuis Last name of sampler or witnessed byAcosta
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSecurity Paving La Mirada Transportation Laboratory (TL) Number6999
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedbelt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberG3-15-STR-002 Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-02-25-40-1CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven DryingLuis Acosta, CT D07 - Plant Services03/04/2022Luis Acosta
Yes
06/10/2022
2022-02-25-40-2CTM 217-June 2011: Method of Test for Sand EquivalentLuis Acosta, CT D07 - Plant Services03/04/2022Luis Acosta
Yes
06/10/2022
2022-02-25-40-3CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesLuis Acosta, CT D07 - Plant Services03/04/2022Luis Acosta
Yes
06/10/2022
2022-02-25-40-4CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Luis Acosta, CT D07 - Plant Services03/04/2022Luis Acosta
Yes
06/10/2022
2022-02-25-40-5CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesLuis Acosta, CT D07 - Plant Services03/04/2022Luis Acosta
Yes
06/10/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-02-25-40-1 CTM 226-July 2010 (Verified)
DIME Test ID: 2022-02-25-40-2 CTM 217-June 2011 (Verified)
DIME Test ID: 2022-02-25-40-3 CTM 202-November 2011 (Verified)
DIME Test ID: 2022-02-25-40-4 CTM 227-December 2014 (Verified)