Sample Record

Owner Lab

  • CT HQ - Sacramento Aggregate Testing Laboratory

DIME Sample ID 2022-03-23-36

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/23/2022 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2022
Sample typeAggregate Prequalification Program A brief description of the sample1x4 Gravel
The quantity of what the sample constitutes6 Buckets From where was the sample collectedSupplier
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byMyers
Title of samplerQC Supervisor Telephone number of sampler559-477-6228
Laboratory sample identification22-APPC-0088 Linked DIME Sample ID2022-03-23-31
The fabricator/manufacturer/facility nameCemex Rockfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0014
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number4401 A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-03-23-36-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesJay Horton, CT HQ - Sacramento Aggregate Testing Laboratory06/13/2022Bang Nguyen
Yes
06/28/2022
2022-03-23-36-2CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Jay Horton, CT HQ - Sacramento Aggregate Testing Laboratory06/15/2022Bang Nguyen
Yes
06/28/2022
2022-03-23-36-3CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing MachineJay Horton, CT HQ - Sacramento Aggregate Testing Laboratory06/16/2022Bang Nguyen
Yes
06/28/2022
2022-03-23-36-4CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium SulfateRyan Kester/ Jay Horton, CT HQ - Sacramento Aggregate Testing Laboratory06/24/2022Bang Nguyen
Yes
06/28/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-03-23-36-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2022-03-23-36-2 CTM 227-December 2014 (Verified)
DIME Test ID: 2022-03-23-36-3 CTM 211-May 2010 (Verified)
DIME Test ID: 2022-03-23-36-4 CTM 214-August 2010 (Verified)