Sample Record

Owner Lab

  • CT HQ - Sacramento Aggregate Testing Laboratory

DIME Sample ID 2022-04-30-40

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/30/2022 Sample Unique Key40
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/18/2022
Sample typeVerification A brief description of the sample1/2" HMA, WMA, 15% RAP, PG 64-10
The quantity of what the sample constitutes 6 Bags From where was the sample collectedSupplier
First name of sampler or witnessed byErika Last name of sampler or witnessed byGonzalez
Title of sampler Telephone number of sampler
Laboratory sample identification22-JMFPP-0077 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Pleasanton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0009
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedColdfeed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-04-30-40-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Bang Nguyen/ Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory05/20/2022Bang Nguyen
Yes
05/20/2022
2022-04-30-40-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory05/19/2022Bang Nguyen
Yes
05/25/2022Bulk specific gravity (SSD) of fine aggregate, Bulk specific gravity of fine aggregate, Apparent specific gravity of fine aggregate, Apparent specific gravity of supplemental fines, Absorption of fine aggregate
2022-04-30-40-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory05/19/2022Bang Nguyen
Yes
05/25/2022Bulk specific gravity (oven dry) of coarse aggregate and Absorption of coarse aggregate
2022-04-30-40-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Bang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory05/24/2022Bang Nguyen
Yes
05/25/2022Los Angeles Rattler, Loss at 100 and 500 Rev.
2022-04-30-40-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Bang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory05/19/2022Bang Nguyen
Yes
05/25/2022Sand equivalent (min)
2022-04-30-40-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Bang Nguyen, CT HQ - Sacramento Aggregate Testing Laboratory05/25/2022Bang Nguyen
Yes
05/25/2022Method A
2022-04-30-40-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory05/25/2022Bang Nguyen
Yes
05/26/2022Crushed particles, coarse aggregate One fractured face and Crushed particles, coarse aggregate Two fractured faces - Method 1 Crushed particles, fine aggregate (Passing No. 4 sieve and retained on No. 8 sieve) One fractured face - Method 2
2022-04-30-40-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory05/25/2022Bang Nguyen
Yes
05/26/2022Flat and elongated particles (% by mass at 5:1)

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-04-30-40-1 AASHTO T27-14 (Verified)
DIME Test ID: 2022-04-30-40-2 AASHTO T84-14 (Verified)
DIME Test ID: 2022-04-30-40-3 AASHTO T85-13 (Verified)
DIME Test ID: 2022-04-30-40-4 AASHTO T96-02r10 (Verified)
DIME Test ID: 2022-04-30-40-5 AASHTO T176-08 (Verified)
DIME Test ID: 2022-04-30-40-6 AASHTO T304-11 (Verified)
DIME Test ID: 2022-04-30-40-7 AASHTO T335-09r13 (Verified)
DIME Test ID: 2022-04-30-40-8 ASTM D4791-10 (Verified)