Sample Record

Owner Labs

  • Kwik Bond Polymers
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2022-05-16-19

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 993334
DEA: 051M3704
EFIS: 0519000130
DIST-CO-RTE-PM05-SB-154-23.8/29.2
Award Date12/17/2021
Closeout Date10/20/2022
Work DescriptionCOLD PLANE EXISTING PAVEMENT, PLACE HMA-A AND HFST OVERLAY.
Location DescriptionSANTA BARBARA COUNTY NEAR SANTA BARBARA AT VARIOUS LOCATIONS FROM 0.4 MILE EAST OF STAGECOACH ROAD TO 0.8 MILE WEST OF SAN ANTONIO CREEK ROAD
QA Service Level1 (Verified on 11/16/2021)

Sample Information

Sample Taken Date05/16/2022 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/17/2022
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes32 Totes From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler707-624-5467
Laboratory sample identification Linked DIME Sample ID943110
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) Number943110
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypePolyester Mfg. Lot Number(s)T001406363
Batch numberT001406363 Mix numberT001406363

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-05-16-19-1ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational ViscometerRachael Chavez, CT HQ - Sacramento Concrete Testing Laboratory06/01/2022Phillip Montes
Yes
06/30/2022
2022-05-16-19-2ASTM D638-Dec14: Standard Test Method for Tensile Properties of PlasticsLinda Bergstrom, CT HQ - Sacramento Concrete Testing Laboratory05/19/2022Phillip Montes
Yes
06/30/2022Accepted vendor's results. Caltrans Chemistry results: Gel Time (ASTM C881) = 25 minutes Cure Rate (ASTM D1640) = 1.5 hours

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-05-16-19-1 ASTM D2196-Feb15 (Verified)
DIME Test ID: 2022-05-16-19-2 ASTM D638-Dec14 (Verified)