Sample Record

Owner Lab

  • Vulcan Materials Company - San Diego

DIME Sample ID 2014-12-10-10

Project Information

Project IdentifiersProject ID: 7780
DEA: 112T1824
EFIS: 1100020051
DIST-CO-RTE-PM11-SD-805-4.7/5.6
Award Date01/03/2013
Closeout Date09/07/2018
Work DescriptionREPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
QA Service Level1 (Verified on 12/10/2012)

Sample Information

Sample Taken Date12/10/2014 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/11/2014
Sample typeQuality Control A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes5 cylinders From where was the sample collectedSource
First name of sampler or witnessed byJTJ Last name of sampler or witnessed byRMA
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample ID2014-12-10-1001-8954
The fabricator/manufacturer/facility nameVulcan Mission Valley Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design number103612F
The truck number from where the sample was collected441 The batch plant ticket number from where the sample was collected141629
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedretaining wall 18L Coping Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2014-12-10-10-1ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteJTJ RMA, Vulcan Materials Company - San Diego12/10/2014JTJ RMA
Yes
01/30/2015
2014-12-10-10-2ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement ConcreteJTJ RMA, Vulcan Materials Company - San Diego12/10/2014JTJ RMA
Yes
01/30/2015
2014-12-10-10-3ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensJTJ RMA, Vulcan Materials Company - San Diego12/17/2014JTJ RMA
Yes
01/30/2015
2014-12-10-10-4ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensJTJ RMA, Vulcan Materials Company - San Diego01/07/2015JTJ RMA
Yes
01/30/2015

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2014-12-10-10-1 ASTM C1064-08 (Verified)
DIME Test ID: 2014-12-10-10-2 ASTM C143-10a (Verified)
DIME Test ID: 2014-12-10-10-3 ASTM C39-10 (Verified)
DIME Test ID: 2014-12-10-10-4 ASTM C39-10 (Verified)