Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2022-03-21-7
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214099 DEA: 024F5904 EFIS: 0213000010 |
---|---|
DIST-CO-RTE-PM | 02-TEH-5-R25.4 |
Award Date | 07/08/2020 |
Closeout Date | 08/14/2023 |
Work Description | BRIDGE SEISMIC RETROFIT AND SCOUR REPAIR. |
Location Description | TEHAMA COUNTY IN RED BLUFF AT SACRAMENTO RIVER BRIDGE |
QA Service Level | 1 (Verified on 05/07/2019) |
Sample Information
Sample Taken Date | 03/21/2022 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/06/2022 |
Sample type | Quality Assurance | A brief description of the sample | 7/8" x 3 1/4" A325 HDG fastenersh nuts and washers |
The quantity of what the sample constitutes | 170 fastener assemblies | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Linked DIME Sample ID | 2022-3-21-6 | |
The fabricator/manufacturer/facility name | C&K Johnson | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-039-22 | Structure unique identifier | 08-0095 R/L |
Structure name | Sacramento River Bridge- I5 |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 452406AR |
---|---|---|---|
Heat Number(s) | Bolt 100105211 nut-8000008883 washer 12021060 | Nut Mfg. Lot Number(s) | 458829A |
Washer Mfg. Lot Number(s) | D9779 | Bolt Specification | A325 |
Bolt Length(s) | 3 1/4" | Nut Specification | A563 dh |
Washer Specification | F436 | Finish | HDGalv |
Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 452406A |
Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | yes |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2022-03-21-7-1 ASTM F606-21 (Verified)
DIME Test ID: 2022-03-21-7-2 ASTM F606-21 (Verified)
DIME Test ID: 2022-03-21-7-3 ASME B1.2-83r17 (Verified)
DIME Test ID: 2022-03-21-7-4 ASME B1.2-83r17 (Verified)
DIME Test ID: 2022-03-21-7-5 ASME B1.2-83r17 (Verified)
DIME Test ID: 2022-03-21-7-6 ASME B1.2-83r17 (Verified)
DIME Test ID: 2022-03-21-7-7 ASME B1.2-83r17 (Verified)
DIME Test ID: 2022-03-21-7-8 ASME B1.2-83r17 (Verified)
DIME Test ID: 2022-03-21-7-9 ASTM B499-09r21 (Verified)
DIME Test ID: 2022-03-21-7-10 ASTM B499-09r21 (Verified)
DIME Test ID: 2022-03-21-7-11 ASTM B499-09r21 (Verified)
DIME Test ID: 2022-03-21-7-12 ASTM B499-09r21 (Verified)
DIME Test ID: 2022-03-21-7-13 ASTM B499-09r21 (Verified)
DIME Test ID: 2022-03-21-7-14 ASTM B499-09r21 (Verified)
DIME Test ID: 2022-03-21-7-15 ASTM B499-09r21 (Verified)
DIME Test ID: 2022-03-21-7-16 ASTM B499-09r21 (Verified)
DIME Test ID: 2022-03-21-7-17 ASTM B499-09r21 (Verified)
DIME Test ID: 2022-03-21-7-18 ASTM E18-20 (Verified)
DIME Test ID: 2022-03-21-7-19 ASTM E18-20 (Verified)