Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2022-03-18-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209820
DEA: 04297634
EFIS: 0415000040
COOP: 042548
DIST-CO-RTE-PM04-ALA-84,680-17.9/21
Award Date02/19/2021
Closeout DateNot set
Work DescriptionROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location DescriptionALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
QA Service Level1 (Verified on 11/04/2019)

Sample Information

Sample Taken Date03/18/2022 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/22/2022
Sample typeQuality Assurance A brief description of the sample#6 HRC 150 T Heads
The quantity of what the sample constitutes805 From where was the sample collectedManufacturer
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHeaded Reinforcement Corp, Fountain Valley, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-032-22 Structure unique identifier
Structure nameCalaveras SB Bent 2 FTG ETC

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)6028040 Head Manufacturer Lot Number(s)10020904124
Rebar Size#6 Headed Bar Model NameHRC 150
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC
Head ManufacturerNucor Head FabricatorNucor
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-03-18-6-1ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory03/24/2022spaine
Yes
03/28/2022ok necking
2022-03-18-6-2ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory03/24/2022spaine
Yes
03/28/2022ok necking
2022-03-18-6-3ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory03/24/2022spaine
Yes
03/28/2022ok necking
2022-03-18-6-4ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory03/24/2022spaine
Yes
03/28/2022ok necking
2022-03-18-6-5ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory03/24/2022spaine
Yes
03/28/2022ok necking
2022-03-18-6-6ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory03/24/2022spaine
Yes
03/28/2022ok necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-03-18-6-1 ASTM A970-18 (Verified)
DIME Test ID: 2022-03-18-6-2 ASTM A970-18 (Verified)
DIME Test ID: 2022-03-18-6-3 ASTM A970-18 (Verified)
DIME Test ID: 2022-03-18-6-4 ASTM A970-18 (Verified)
DIME Test ID: 2022-03-18-6-5 ASTM A970-18 (Verified)
DIME Test ID: 2022-03-18-6-6 ASTM A970-18 (Verified)