Sample Record

Owner Lab

  • Con-Fab California Corporation - Lathrop

DIME Sample ID 2022-02-25-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209820
DEA: 04297634
EFIS: 0415000040
COOP: 042548
DIST-CO-RTE-PM04-ALA-84,680-17.9/21
Award Date02/19/2021
Closeout DateNot set
Work DescriptionROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location DescriptionALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
QA Service Level1 (Verified on 11/04/2019)

Sample Information

Sample Taken Date02/25/2022 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/25/2022
Sample typeQuality Control A brief description of the sample1 C.Y. of Concrete
The quantity of what the sample constitutes1 C.Y. of Concrete From where was the sample collectedFabricator
First name of sampler or witnessed byMark Patrick Last name of sampler or witnessed byBaddu
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCon-Fab California, LLC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberVER-95LV
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected4600
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBed 1B, 2nd Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-02-25-8-1ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensFerdinand Rosal, Con-Fab California Corporation - Lathrop02/26/2022Danny Cabias
Yes
02/28/2022
2022-02-25-8-2CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement ConcreteMark Patrick Baddu, Con-Fab California Corporation - Lathrop02/25/2022Danny Cabias
Yes
02/28/2022Flow: 21.5" VSI: 0
2022-02-25-8-3ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteMark Patrick Baddu, Con-Fab California Corporation - Lathrop02/25/2022Danny Cabias
Yes
02/28/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-02-25-8-1 ASTM C39-21 (Verified)
DIME Test ID: 2022-02-25-8-2 CTM 556-January 2018 (Verified)
DIME Test ID: 2022-02-25-8-3 ASTM C1064-17 (Verified)