Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2022-02-23-6

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214337
DEA: 080E33U4
EFIS: 0817000075
DIST-CO-RTE-PM08-SBD-115-R7.3/R10.0
Award Date04/26/2021
Closeout DateNot set
Work DescriptionADD WB AUX & EB DECEL LANES, WIDEN I15 SW CONNECT,RAMPS/BRDG
Location DescriptionSAN BERNARDINO COUNTY IN ONTARIO FROM 0.2 MILE WEST OF CUCAMONGA CREEK BRIDGE TO MILLIKEN AVENUE
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date02/23/2022 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/25/2022
Sample typeQuality Assurance A brief description of the sample#6 hoop 2'-2" diameter
The quantity of what the sample constitutes8 hoops from lot 1 and 3 From where was the sample collectedFabricator
First name of sampler or witnessed byOsiel Last name of sampler or witnessed byRamirez
Title of samplerQuality Assurance Inspector Telephone number of sampler5599740870
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-008-22 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1201036646
Hoop Manufacturer Lot Number(s)Lot 1 and 3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-02-23-6-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory03/02/2022bewing
Yes
03/03/2022Ok Necking
2022-02-23-6-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory03/02/2022bewing
Yes
03/03/2022Ok Necking
2022-02-23-6-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory03/02/2022bewing
Yes
03/03/2022Ok Necking
2022-02-23-6-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory03/02/2022bewing
Yes
03/03/2022Ok Necking
2022-02-23-6-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory03/02/2022bewing
Yes
03/03/2022Ok Necking
2022-02-23-6-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory03/02/2022bewing
Yes
03/03/2022Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-02-23-6-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-02-23-6-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-02-23-6-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-02-23-6-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-02-23-6-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-02-23-6-6 CTM 670-December 2013 (Verified)