Sample Record
Owner Lab
- Viking Construction Company, Incorporated - Rancho Cordova
DIME Sample ID 2014-10-22-7
Project Information
Project Identifiers | Project ID: 209175 DEA: 030F2204 EFIS: 0300000072 |
---|---|
DIST-CO-RTE-PM | 03-ED-50-R30.7/R31.7 |
Award Date | 02/25/2014 |
Closeout Date | 07/30/2015 |
Work Description | REPLACE BRIDGE. |
Location Description | SLY PARK UNDERCROSSING |
QA Service Level | 1 (Verified on 11/01/2013) |
Sample Information
Sample Taken Date | 10/22/2014 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/22/2014 |
Sample type | Quality Control | A brief description of the sample | WB 50 West Approach |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Andrew | Last name of sampler or witnessed by | Santos |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | 0 |
The fabricator/manufacturer/facility name | Folsom Ready Mix | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | WB 50 West Approach |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Folsom Ready Mix Stockpile |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2014-10-22-7-1 ASTM C136-06 (Verified)
DIME Test ID: 2014-10-22-7-2 ASTM C136-06 (Verified)
DIME Test ID: 2014-10-22-7-3 ASTM C136-06 (Verified)
DIME Test ID: 2014-10-22-7-4 ASTM C117-04 (Verified)
DIME Test ID: 2014-10-22-7-5 ASTM C566-04 (Verified)
DIME Test ID: 2014-10-22-7-6 ASTM D2419-09 (Verified)