Sample Record

Owner Lab

  • CT D05 - Prunedale Field Laboratory

DIME Sample ID 2022-01-06-51

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 993236
DEA: 051K0504
EFIS: 0518000114
DIST-CO-RTE-PM05-MON-1-55.7/55.9
Award Date10/14/2021
Closeout Date09/02/2022
Work DescriptionCONSTRUCT EARTH RETAINING SYSTEM WITH CIDH PILE & STRUCTURAL CONCRETE.
Location DescriptionMONTEREY COUNTY NEAR LITTLE SUR RIVER FROM 0.4 MILE SOUTH OF LITTLE SUR RIVER BRIDGE TO 0.2 MILE SOUTH OF LITTLE SUR RIVER BRIDGE
QA Service Level1 (Verified on 10/06/2021)

Sample Information

Sample Taken Date01/06/2022 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/06/2022
Sample typeAcceptance A brief description of the sampleAggregate
The quantity of what the sample constitutes4 CY From where was the sample collectedOther
First name of sampler or witnessed byWesley Last name of sampler or witnessed byRider
Title of samplerTET Telephone number of sampler
Laboratory sample identification0106220800 Linked DIME Sample ID
The fabricator/manufacturer/facility nameLas Animas, Marina CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberM779PR50S
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected199196
Concrete batch plantLas Animas Concrete The fabricator/manufacturer designation for the sampleAM 493
A detailed description of where the material sample was collectedconveyor belt Where the material sample would have been placed if not sampledCIDH Piles
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-01-06-51-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersWesley Rider, CT D05 - Prunedale Field Laboratory02/03/2022Wesley Rider
Yes
02/14/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-01-06-51-1 CTM 521-June 2020 (Verified)