Sample Record

Owner Lab

  • RMA Group - Rancho Cordova

DIME Sample ID 2022-01-25-35

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214114
DEA: 040A5394
EFIS: 0418000244
DIST-CO-RTE-PM04-SOL-80,12-11.4/12.8, 2.1/2.8
Award DateNot set
Closeout Date02/24/2023
Work DescriptionWiden EB SR-12 Connector, Construct 3 ramps & 2 box girder bridges, remove existing bridge, etc.
Location DescriptionI-80/I-680/Route 12 Interchange
QA Service Level1 (Verified on 04/23/2019)

Sample Information

Sample Taken Date01/25/2022 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/25/2022
Sample typeQuality Control A brief description of the sampleConcrete
The quantity of what the sample constitutes100 CY From where was the sample collectedJob Site
First name of sampler or witnessed byErik Last name of sampler or witnessed byHaagensen
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSyar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberCT063AC5
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected8114614
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedStorm inlet DS-8A Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-01-25-35-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteErik Haagensen, RMA Group - Rancho Cordova01/25/2022Mathew Lowrance
Yes
03/31/2022
2022-01-25-35-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteErik Haagensen, RMA Group - Rancho Cordova01/25/2022Mathew Lowrance
Yes
03/31/2022
2022-01-25-35-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova02/01/2022Mathew Lowrance
Yes
03/31/2022
2022-01-25-35-4CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova02/22/2022Mathew Lowrance
Yes
03/31/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-01-25-35-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2022-01-25-35-2 ASTM C143-20 (Verified)
DIME Test ID: 2022-01-25-35-3 CTM 521-June 2020 (Verified)
DIME Test ID: 2022-01-25-35-4 CTM 521-June 2020 (Verified)