Sample Record

Owner Lab

  • CT D11 - District 11 Materials Laboratory

DIME Sample ID 2022-01-24-12

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213811
DEA: 112T2184
EFIS: 1116000174
DIST-CO-RTE-PM11-SD-5-R38.4/R47.3
Award Date10/29/2018
Closeout Date01/03/2024
Work Description(Alternative Delivery) Construct HOV lanes, soundwalls, culvert rehab, ITS, and bike trail on I-5 . NCC I-5 Highway Improvement.
Location DescriptionIN SAN DIEGO COUNTY IN ENCINITAS AND CARLSBAD FROM SAN ELIJO LAGOON BRIDGE TO 0.3 MILE NORTH OF PALOMAR AIRPORT ROAD OVERCROSSING.
QA Service Level1 (Verified on 12/19/2018)

Sample Information

Sample Taken Date01/24/2022 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/25/2022
Sample typeQuality Assurance A brief description of the sample1/2" HMA-O
The quantity of what the sample constitutes2 Boxes, 2 Bags, 2 Cans From where was the sample collectedSource
First name of sampler or witnessed byMARCO Last name of sampler or witnessed byESTUDILLO
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-37-0035::CHULA VISTA
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAt Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-01-24-12-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Daniel Smith, CT D11 - District 11 Materials Laboratory01/28/2022Daniel Smith
Yes
02/01/2022Pass
2022-01-24-12-2AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Daniel Smith, CT D11 - District 11 Materials Laboratory01/28/2022Daniel Smith
Yes
02/01/2022Pass
2022-01-24-12-3ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Mohammed Abbassi, CT D11 - District 11 Materials Laboratory01/28/2022Daniel Smith
Yes
02/01/2022Pass
2022-01-24-12-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Daniel Smith, CT D11 - District 11 Materials Laboratory01/28/2022Daniel Smith
Yes
02/01/2022Pass

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-01-24-12-1 AASHTO T27-14 (Verified)
DIME Test ID: 2022-01-24-12-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2022-01-24-12-3 ASTM D4791-10 (Verified)
DIME Test ID: 2022-01-24-12-4 AASHTO T96-02r10 (Verified)