Sample Record

Owner Lab

  • CT HQ - QASI Sacramento Field Office

DIME Sample ID 2022-01-18-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214469
DEA: 030H08U4
EFIS: 0319000029
DIST-CO-RTE-PM03-SAC-50-L0.2/R6.1
Award Date06/30/2020
Closeout DateNot set
Work DescriptionSac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location DescriptionFROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date01/18/2022 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/21/2022
Sample typeVerification A brief description of the sample#5 headed bar
The quantity of what the sample constitutes1 lot of 150 From where was the sample collectedFabricator
First name of sampler or witnessed byMichael Last name of sampler or witnessed byFoerder
Title of samplerQAI Telephone number of sampler7076850968
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartinez Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB285-004-22 Structure unique identifier
Structure nameElmhurst Viaduct

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)54183637 Head Manufacturer Lot Number(s)6Y6
Rebar Size#5 Headed Bar Model NameBNX Buttonhead
Size of HeadFull Size - 9x Head Connection TypeCrimped Head
Head ShapeCircular Rebar ManufacturerGerdau
Head ManufacturerBarSplice Products Head FabricatorBarsplice
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-01-18-7-1ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory01/25/2022spaine
Yes
01/25/2022ok necking
2022-01-18-7-2ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory01/25/2022spaine
Yes
01/25/2022ok necking
2022-01-18-7-3ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory01/25/2022spaine
Yes
01/25/2022ok necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-01-18-7-1 ASTM A970-18 (Verified)
DIME Test ID: 2022-01-18-7-2 ASTM A970-18 (Verified)
DIME Test ID: 2022-01-18-7-3 ASTM A970-18 (Verified)