Sample Record
Owner Lab
- CT HQ - Sacramento Concrete Testing Laboratory
DIME Sample ID 2022-01-04-9
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 215492 DEA: 051K7004 EFIS: 0518000231 |
---|---|
DIST-CO-RTE-PM | 05-MON-1-64.4 |
Award Date | 04/05/2021 |
Closeout Date | 08/14/2023 |
Work Description | TREAT EXISTING STRUCTURE WITH ELECTROCHEMICAL CHLORIDE EXTRACTION. |
Location Description | MONTEREY COUNTY NEAR CARMEL-BY-THE SEA AT GRANITE CANYON BRIDGE |
QA Service Level | 1 (Verified on 03/12/2021) |
Sample Information
Sample Taken Date | 01/04/2022 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/04/2022 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | 6 Cylinders | From where was the sample collected | Other |
First name of sampler or witnessed by | Spencer | Last name of sampler or witnessed by | Adams |
Title of sampler | MREAS | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Concrete Lab | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | SikaTop 123 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | Unknown | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Mixer | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2022-01-04-9-1 ASTM C39-17a (Verified)
DIME Test ID: 2022-01-04-9-2 ASTM C469-14 (Verified)
DIME Test ID: 2022-01-04-9-3 CTM 550-December 2013 (Verified)
DIME Test ID: 2022-01-04-9-4 CTM 417-June 2014 (Verified)
DIME Test ID: 2022-01-04-9-5 CTM 422-June 2014 (Verified)