Sample Record

Owner Lab

  • RMA Group - Rancho Cordova

DIME Sample ID 2021-09-11-10

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215396
DEA: 042K8404
EFIS: 0417000031
DIST-CO-RTE-PM04-SOL-29,80-0.0,0.8/1.6
Award Date03/26/2021
Closeout Date02/16/2024
Work DescriptionHMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR.
Location DescriptionSOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING
QA Service Level1 (Verified on 01/25/2021)

Sample Information

Sample Taken Date09/11/2021 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2021
Sample typeQuality Control A brief description of the sampleConcrete
The quantity of what the sample constitutes100 cy From where was the sample collectedJob Site
First name of sampler or witnessed byPedro Last name of sampler or witnessed byDe Haro
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number1613820
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected29849433
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCDIH Foundation Stage 1 Abutment 3 Pile 3 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-09-11-10-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcretePedro De Haro, RMA Group - Rancho Cordova09/11/2021Mathew Lowrance
Yes
04/13/2022
2021-09-11-10-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodPedro De Haro, RMA Group - Rancho Cordova09/11/2021Mathew Lowrance
Yes
04/13/2022
2021-09-11-10-3CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcretePedro De Haro, RMA Group - Rancho Cordova09/11/2021Mathew Lowrance
Yes
04/13/2022
2021-09-11-10-4ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcretePedro De Haro, RMA Group - Rancho Cordova09/11/2021Mathew Lowrance
Yes
04/13/2022
2021-09-11-10-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova10/09/2021Mathew Lowrance
Yes
04/13/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-09-11-10-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2021-09-11-10-2 CTM 504-June 2010 (Verified)
DIME Test ID: 2021-09-11-10-3 CTM 518-June 2010 (Verified)
DIME Test ID: 2021-09-11-10-4 ASTM C143-20 (Verified)
DIME Test ID: 2021-09-11-10-5 CTM 521-June 2020 (Verified)