Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2021-11-23-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215744
DEA: 033H93U4
EFIS: 0321000091
DIST-CO-RTE-PM03-YUB,BUT-70-25.5/25.8,0.0/3.8
Award Date07/15/2021
Closeout DateNot set
Work DescriptionWIDEN ROADWAY & SHOULDER, ADD TURN LANES & CONSTRUCT BRIDGE.
Location DescriptionYUBA AND BUTTE COUNTIES ABOUT 11 MILES NORTH OF MARYSVILLE FROM 0.8 MILE NORTH OF CHANDLER ROAD TO 0.2 MILE SOUTH OF EAST GRIDLEY ROAD
QA Service Level1 (Verified on 05/20/2021)

Sample Information

Sample Taken Date11/23/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/29/2021
Sample typeQuality Assurance A brief description of the sample Flash Welded Hoops
The quantity of what the sample constitutes450 From where was the sample collectedFabricator
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of sampler Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-189-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1201029667
Hoop Manufacturer Lot Number(s)1 and 3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop7'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor Utah
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-11-23-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/30/2021bewing
Yes
12/01/2021Ok Necking
2021-11-23-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/30/2021bewing
Yes
12/01/2021Ok Necking
2021-11-23-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/30/2021bewing
Yes
12/01/2021Ok Necking
2021-11-23-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/30/2021bewing
Yes
12/01/2021Ok Necking
2021-11-23-1-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/30/2021bewing
Yes
12/01/2021Ok Necking
2021-11-23-1-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/30/2021bewing
Yes
12/01/2021Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-11-23-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-11-23-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-11-23-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-11-23-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-11-23-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-11-23-1-6 CTM 670-December 2013 (Verified)