Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2021-11-10-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 993322
DEA: 010L4204
EFIS: 0122000008
DIST-CO-RTE-PM01-MEN,MEN/MEN-101-4/6, 4.0/6.0
Award Date08/23/2021
Closeout DateNot set
Work DescriptionLandslide Repair near Commisky
Location DescriptionNot set
QA Service Level1 (Verified on 10/11/2021)

Sample Information

Sample Taken Date11/10/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/18/2021
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes150 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byCarpenter
Title of samplerQA Telephone number of sampler14156081742
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameConco Reinforcing Benicia Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB24-095-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateService Rebar Heat Number(s)251021
Hoop Manufacturer Lot Number(s)H26, H27, H28 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop5'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyConco Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-11-10-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory11/22/2021fsaylor
Yes
11/22/2021OK Necking
2021-11-10-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory11/22/2021fsaylor
Yes
11/22/2021OK Necking
2021-11-10-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory11/22/2021fsaylor
Yes
11/22/2021OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-11-10-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-11-10-5-2 CTM 670-December 2013 (Verified)