Sample Record

Owner Lab

  • CT HQ - Sacramento Aggregate Testing Laboratory

DIME Sample ID 2021-08-12-56

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/12/2021 Sample Unique Key56
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/01/2021
Sample typePer Request A brief description of the sample3/4" HMA (Drum Plant)
The quantity of what the sample constitutes_ From where was the sample collectedManufacturer
First name of sampler or witnessed byHarish Last name of sampler or witnessed byThakur
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2021-08-12-42
The fabricator/manufacturer/facility nameGranite Pleasanton Transportation Laboratory (TL) Number21-JMF-0194
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0009
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-08-12-56-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory11/02/2021Bang Nguyen
Yes
11/10/2021
2021-08-12-56-2AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory11/04/2021Bang Nguyen
Yes
11/10/2021
2021-08-12-56-3AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory11/03/2021Bang Nguyen
Yes
11/10/2021
2021-08-12-56-4AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory11/02/2021Bang Nguyen
Yes
11/10/2021
2021-08-12-56-5AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory11/02/2021Bang Nguyen
Yes
11/10/2021

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-12-56-1 AASHTO T27-14 (Verified)
DIME Test ID: 2021-08-12-56-2 AASHTO T335-09r13 (Verified)
DIME Test ID: 2021-08-12-56-3 AASHTO T84-14 (Verified)
DIME Test ID: 2021-08-12-56-4 AASHTO T176-08 (Verified)
DIME Test ID: 2021-08-12-56-5 AASHTO T304-11 (Verified)