Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2021-10-26-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215396
DEA: 042K8404
EFIS: 0417000031
DIST-CO-RTE-PM04-SOL-29,80-0.0,0.8/1.6
Award Date03/26/2021
Closeout Date02/16/2024
Work DescriptionHMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR.
Location DescriptionSOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING
QA Service Level1 (Verified on 01/25/2021)

Sample Information

Sample Taken Date10/26/2021 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/28/2021
Sample typeQuality Assurance A brief description of the sample#5 Rebar Couplers
The quantity of what the sample constitutes4 ea- Lots C01, C02 From where was the sample collectedSupplier
First name of sampler or witnessed byRyan Last name of sampler or witnessed byParr
Title of samplerASI Telephone number of sampler510-385-5910
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameConco Reinforcing Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB373-102-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A615
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerEaton Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelErico Lenton Standard
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)L-9821 Rebar Heat Number(s)3500020934
Rebar Size 2 5 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-10-26-9-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/29/2021bewing
Yes
11/01/2021Service Splice
2021-10-26-9-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/29/2021bewing
Yes
11/01/2021Service Splice
2021-10-26-9-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/29/2021bewing
Yes
11/01/2021Service Splice
2021-10-26-9-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/29/2021bewing
Yes
11/01/2021Service Splice
2021-10-26-9-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/29/2021bewing
Yes
11/01/2021Service Splice
2021-10-26-9-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/29/2021bewing
Yes
11/01/2021Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-10-26-9-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-10-26-9-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-10-26-9-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-10-26-9-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-10-26-9-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-10-26-9-6 CTM 670-December 2013 (Verified)