Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2021-10-12-26

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215083
DEA: 07307504
EFIS: 0714000217
DIST-CO-RTE-PM07-LA-101-11.8/31.1
Award Date09/21/2020
Closeout Date08/25/2022
Work DescriptionPLACE RHMA-G, MODIFY RAMP METERING AND SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionLOS ANGELES COUNTY FROM TUJUNGA AVENUE UNDERCROSSING TO LAS VIRGENES ROAD OVERCROSSING
QA Service Level1 (Verified on 11/18/2020)

Sample Information

Sample Taken Date10/12/2021 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/14/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15, 0.5% LAS
The quantity of what the sample constitutes10 Bags of Aggregate, 1 Bag of RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler
Laboratory sample identification0588A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035::FISH CANYON QUARRY
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number220831 SVA SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-10-12-26-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Dominic Montemayor, Edmond Jabbour, CT D08 - Fontana Southern Regional Laboratory10/15/2021Michael Magana
Yes
10/25/2021Combined Virgin Aggregate Gradation
2021-10-12-26-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Friday Ofoegbu, CT D08 - Fontana Southern Regional Laboratory10/16/2021Michael Magana
Yes
10/25/2021
2021-10-12-26-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)Larry Diaz, CT D08 - Fontana Southern Regional Laboratory10/16/2021Michael Magana
Yes
10/25/2021
2021-10-12-26-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Edmond Jabbour, CT D08 - Fontana Southern Regional Laboratory10/18/2021Michael Magana
Yes
10/25/2021
2021-10-12-26-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Edmond Jabbour, CT D08 - Fontana Southern Regional Laboratory10/18/2021Michael Magana
Yes
10/25/2021
2021-10-12-26-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Michael Magana, CT D08 - Fontana Southern Regional Laboratory10/18/2021Michael Magana
Yes
10/25/2021
2021-10-12-26-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Michael Magana, CT D08 - Fontana Southern Regional Laboratory10/18/2021Michael Magana
Yes
10/25/2021
2021-10-12-26-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Michael Magana, CT D08 - Fontana Southern Regional Laboratory10/18/2021Michael Magana
Yes
10/25/2021
2021-10-12-26-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesEdmond Jabbour, CT D08 - Fontana Southern Regional Laboratory10/18/2021Michael Magana
Yes
10/25/2021RAP Gradation After Ignition Oven
2021-10-12-26-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesDominic Montemayor, Edmond Jabbour, CT D08 - Fontana Southern Regional Laboratory10/18/2021Michael Magana
Yes
10/25/2021Combined RAP/Virgin Aggregate Gradation w/Correlation Factors Applied

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-10-12-26-1 AASHTO T27-14 (Verified)
DIME Test ID: 2021-10-12-26-2 AASHTO T84-14 (Verified)
DIME Test ID: 2021-10-12-26-3 AASHTO T85-13 (Verified)
DIME Test ID: 2021-10-12-26-4 AASHTO T96-02r10 (Verified)
DIME Test ID: 2021-10-12-26-5 AASHTO T176-08 (Verified)
DIME Test ID: 2021-10-12-26-6 AASHTO T304-11 (Verified)
DIME Test ID: 2021-10-12-26-7 AASHTO T335-09r13 (Verified)
DIME Test ID: 2021-10-12-26-8 ASTM D4791-10 (Verified)
DIME Test ID: 2021-10-12-26-9 CTM 202-November 2011 (Verified)
DIME Test ID: 2021-10-12-26-10 CTM 202-November 2011 (Verified)