Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-10-18-19

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214469
DEA: 030H08U4
EFIS: 0319000029
DIST-CO-RTE-PM03-SAC-50-L0.2/R6.1
Award Date06/30/2020
Closeout DateNot set
Work DescriptionSac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location DescriptionFROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date10/18/2021 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/13/2021
Sample typeQuality Assurance A brief description of the sampleBarsplice Button Head End Anchor
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed bythao Last name of sampler or witnessed byYang
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCascade Barsplice Transportation Laboratory (TL) NumberC766280
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)496520 Head Manufacturer Lot Number(s)2
Rebar Size#8 Headed Bar Model NameBarsplice Buttonhead
Size of HeadFull Size - 9x Head Connection TypeCrimped Head
Head ShapeCircular Rebar ManufacturerCascade
Head ManufacturerBarsplice Head FabricatorBarsplice
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-10-18-19-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/21/2021bewing
Yes
10/21/2021Ok Necking
2021-10-18-19-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/21/2021bewing
Yes
10/21/2021Ok Necking
2021-10-18-19-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory10/21/2021bewing
Yes
10/21/2021Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-10-18-19-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-18-19-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2021-10-18-19-3 ASTM A970-15e1 (Verified)