Sample Record
Owner Lab
- Viking Construction Company, Incorporated - Rancho Cordova
DIME Sample ID 2014-07-30-5304339
Project Information
Project Identifiers | Project ID: 209175 DEA: 030F2204 EFIS: 0300000072 |
---|---|
DIST-CO-RTE-PM | 03-ED-50-R30.7/R31.7 |
Award Date | 02/25/2014 |
Closeout Date | 07/30/2015 |
Work Description | REPLACE BRIDGE. |
Location Description | SLY PARK UNDERCROSSING |
QA Service Level | 1 (Verified on 11/01/2013) |
Sample Information
Sample Taken Date | 07/30/2014 | Sample Unique Key | 5304339 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/30/2014 |
Sample type | Quality Control | A brief description of the sample | Approach Slab Aggregate |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Andrew | Last name of sampler or witnessed by | Santos |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | Not set | |
The fabricator/manufacturer/facility name | Folsom Ready Mix | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Folsom Ready Mix Stockpile |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Folsom Ready Mix Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | ||
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2014-07-30-5304339-1 ASTM C136-06 (Verified)
DIME Test ID: 2014-07-30-5304339-2 ASTM C117-04 (Verified)
DIME Test ID: 2014-07-30-5304339-3 ASTM C566-04 (Verified)
DIME Test ID: 2014-07-30-5304339-4 ASTM D2419-09 (Verified)