Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2021-09-21-21

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214336
DEA: 07302404
EFIS: 0713000488
DIST-CO-RTE-PM07-VEN-101-37/40
Award DateNot set
Closeout DateNot set
Work DescriptionPADRE JUAN REHAB
Location DescriptionVEN 101
QA Service Level1 (Verified on 02/26/2021)

Sample Information

Sample Taken Date09/21/2021 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/24/2021
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R25 No LAS
The quantity of what the sample constitutes4 Bags Coldfeed Aggregate, 2 Bags of RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byEsequil Last name of sampler or witnessed byOrtega
Title of sampler Telephone number of sampler
Laboratory sample identification0550A-21 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046::BIG ROCK CREEK- GRANITE
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R25 The fabricator/manufacturer designation for the sample
The plant number13762 A detailed description of where the material sample was collectedBelt Cut at Granite Santa Paula Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number1 Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-09-21-21-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Satish Jain/Larry Diaz, CT D08 - Fontana Southern Regional Laboratory09/25/2021Satish Jain
Yes
10/01/2021Combined Virgin Aggregate Gradation
2021-09-21-21-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Danilo Ferrer, CT D08 - Fontana Southern Regional Laboratory09/27/2021Satish Jain
Yes
10/01/2021
2021-09-21-21-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)Edmond Jabbour, CT D08 - Fontana Southern Regional Laboratory09/27/2021Satish Jain
Yes
10/01/2021
2021-09-21-21-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Edmond Jabbour, CT D08 - Fontana Southern Regional Laboratory09/30/2021Satish Jain
Yes
10/01/2021
2021-09-21-21-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Edmond Jabbour, CT D08 - Fontana Southern Regional Laboratory09/29/2021Satish Jain
Yes
10/01/2021
2021-09-21-21-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory09/30/2021Satish Jain
Yes
10/01/2021
2021-09-21-21-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory09/30/2021Satish Jain
Yes
10/01/2021
2021-09-21-21-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Satish Jain, CT D08 - Fontana Southern Regional Laboratory09/30/2021Satish Jain
Yes
10/01/2021
2021-09-21-21-9CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesSatish Jain, CT D08 - Fontana Southern Regional Laboratory09/30/2021Satish Jain
Yes
10/01/2021Rap Gradation After Ignition
2021-09-21-21-10CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesSatish Jain/Larry Diaz, CT D08 - Fontana Southern Regional Laboratory09/30/2021Satish Jain
Yes
10/01/2021Combined Aggregate Gradation W/Rap Gradation Correlation Factors

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-09-21-21-1 AASHTO T27-14 (Verified)
DIME Test ID: 2021-09-21-21-2 AASHTO T84-14 (Verified)
DIME Test ID: 2021-09-21-21-3 AASHTO T85-13 (Verified)
DIME Test ID: 2021-09-21-21-4 AASHTO T96-02r10 (Verified)
DIME Test ID: 2021-09-21-21-5 AASHTO T176-08 (Verified)
DIME Test ID: 2021-09-21-21-6 AASHTO T304-11 (Verified)
DIME Test ID: 2021-09-21-21-7 AASHTO T335-09r13 (Verified)
DIME Test ID: 2021-09-21-21-8 ASTM D4791-10 (Verified)
DIME Test ID: 2021-09-21-21-9 CTM 202-November 2011 (Verified)
DIME Test ID: 2021-09-21-21-10 CTM 202-November 2011 (Verified)