Sample Record

Owner Lab

  • CT - Unassigned/General Field Laboratory

DIME Sample ID 2021-08-03-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208973
DEA: 120H1004
EFIS: 1200000180
COOP: 120670
DIST-CO-RTE-PM12-ORA-405,73,405,605-9.3/24.3
Award Date11/07/2016
Closeout DateNot set
Work Description(Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location DescriptionOrange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
QA Service Level1 (Verified on 09/10/2015)

Sample Information

Sample Taken Date08/03/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/09/2021
Sample typeQuality Assurance A brief description of the sampleASTM A706 GR 60 Hoop
The quantity of what the sample constitutes888 pcs From where was the sample collectedSource
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byClifford
Title of samplerQA Inspector Telephone number of sampler7142674733
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Etiwanda Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL78-055-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4109965
Hoop Manufacturer Lot Number(s)1,2,3,4,5,6 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop5'-4.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Etiwanda Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-08-03-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-3-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-3-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-3-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021
2021-08-03-3-7CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-3-8CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking
2021-08-03-3-9CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/10/2021fsaylor
Yes
08/10/2021OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-03-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-3-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-3-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-3-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-3-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-3-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-03-3-9 CTM 670-December 2013 (Verified)