Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2021-06-10-12

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212775
DEA: 024F2204
EFIS: 0212000073
DIST-CO-RTE-PM02-TRI-3-58.7/61.9
Award Date02/25/2021
Closeout Date05/06/2024
Work DescriptionREPLACE STRUCTURAL CONCRETE BRIDGE AND CULVERTS AND PLACE HMA.
Location DescriptionTRINITY COUNTY NEAR TRINITY CENTER FROM 58.7 MILES NORTH OF PREACHER MEADOWS ROAD TO 60.7 MILES SOUTH OF EL DORADO WAY
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date06/10/2021 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/18/2021
Sample typeQuality Assurance A brief description of the sampleA706 Grade 60 #5 Welded Hoop
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of samplerQA Inspector Telephone number of sampler7073428602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Corp Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL110-073-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1201016559
Hoop Manufacturer Lot Number(s)Lot No 1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop1'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Corp Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-06-10-12-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/21/2021fsaylor
Yes
06/21/2021OK Necking
2021-06-10-12-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/21/2021fsaylor
Yes
06/21/2021OK Necking
2021-06-10-12-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/21/2021fsaylor
Yes
06/21/2021OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-06-10-12-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-06-10-12-2 CTM 670-December 2013 (Verified)