Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2021-05-26-3
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 213521 DEA: 050L7234 EFIS: 0515000099 |
---|---|
DIST-CO-RTE-PM | 05-SLO-58-3.08 |
Award Date | 06/25/2020 |
Closeout Date | 08/23/2023 |
Work Description | TROUT CREEK BRIDGE REPLACEMENT |
Location Description | IN SAN LUIS OBISPO COUNTY ON HWY 58 EAST OF SANTA MARGARITA AT TROUT CREEK BRIDGE (BR NO. 49-0091). |
QA Service Level | 1 (Verified on 09/30/2019) |
Sample Information
Sample Taken Date | 05/26/2021 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/28/2021 |
Sample type | Quality Assurance | A brief description of the sample | Flash welded rebar hoops |
The quantity of what the sample constitutes | 500 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Steve | Last name of sampler or witnessed by | Hall |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 6466327821 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L134-086-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 3500009624 |
Hoop Manufacturer Lot Number(s) | 1 and 4 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #5 |
Diameter of Hoop | 1'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor Seattle |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2021-05-26-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-26-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-26-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-26-3-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-26-3-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-26-3-8 CTM 670-December 2013 (Verified)