Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2021-04-23-2
Project Information
Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
Award Date | 04/21/2020 |
Closeout Date | Not set |
Work Description | Panther Creek & Hunter Creek Bridges |
Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 04/23/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/28/2021 |
Sample type | Department Acceptance | A brief description of the sample | 1" ASTM A709 Gr50T1/T2 Plate |
The quantity of what the sample constitutes | 1 Plate | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9165170532 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Thompson Metal Fab | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-060-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM6 - Steel Check Sample Plate | Heat Number(s) | 0606338 |
---|---|---|---|
Material Specification | A709 | Grade | 50T1/T2 |
Thickness | 1 | Shape | Plate |
Metal Foundry Manufacturer (Mill) | Nucor | Plate Dimension | Unknown |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2021-04-23-2-1 ASTM A370-15 (Verified)
DIME Test ID: 2021-04-23-2-2 ASTM E415-17 (Verified)
DIME Test ID: 2021-04-23-2-3 ASTM E23-12c (Verified)