Sample Record

Owner Lab

  • CT METS QASI - Los Angeles Design Build Field Laboratory

DIME Sample ID 2021-04-01-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214702
DEA: 030F2864
EFIS: 0320000123
DIST-CO-RTE-PM03-SAC-99-7.92 / 8.4
Award Date06/24/2020
Closeout Date11/28/2023
Work DescriptionRemove and replace Consumnes River and Consumnes River Overflow bridge
Location DescriptionSacramento County
QA Service Level1 (Verified on 04/20/2020)

Sample Information

Sample Taken Date04/01/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/05/2021
Sample typeQuality Assurance A brief description of the sample#8 welded hoops (4'-6" dia)
The quantity of what the sample constitutes560 From where was the sample collectedFabricator
First name of sampler or witnessed byMichael Last name of sampler or witnessed byCattabiani
Title of samplerAMR Telephone number of sampler2016746612
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Etiwanda Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4104470
Hoop Manufacturer Lot Number(s)Lots 14 - 17 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop4'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel Arizona
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-04-01-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/06/2021bewing
Yes
04/06/2021Ok Necking
2021-04-01-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/06/2021bewing
Yes
04/06/2021Ok Necking
2021-04-01-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory04/06/2021bewing
Yes
04/06/2021Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-04-01-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-04-01-7-2 CTM 670-December 2013 (Verified)