Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-02-16-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214922
DEA: 100X3104
EFIS: 1013000265
DIST-CO-RTE-PM10-SJ-99-16.8/17.6
Award Date06/30/2020
Closeout Date04/07/2022
Work DescriptionREPLACE BRIDGE.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF FARMINGTON ROAD OVERCROSSING
QA Service Level1 (Verified on 04/28/2020)

Sample Information

Sample Taken Date02/16/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/16/2021
Sample typeQuality Assurance A brief description of the sampleDouble Barrel Zap Screwlok
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byA Last name of sampler or witnessed byjox
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Barsplice Transportation Laboratory (TL) NumberC923931
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelDouble Barrel Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)6342 Rebar Heat Number(s)6019603
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-02-16-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory02/16/2021fsaylor
Yes
02/17/2021Service Splice
2021-02-16-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory02/16/2021fsaylor
Yes
02/17/2021Service Splice
2021-02-16-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory02/16/2021fsaylor
Yes
02/17/2021Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-02-16-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-02-16-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-02-16-4-3 CTM 670-December 2013 (Verified)