Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-02-09-23

Project Information

Project IdentifiersProject ID: 77777
DEA: CHEM-STOCK
EFIS: CHEM-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/09/2021 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/09/2021
Sample typeAuthorization A brief description of the sampleCouplers to qualify for AML
The quantity of what the sample constitutes4 bars with couplers From where was the sample collectedOther
First name of sampler or witnessed byDavid Last name of sampler or witnessed byMurray
Title of sampler Telephone number of sampler9166395549
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBarsplice Nucor Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameN/A

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor - Utah
Coupler ManufacturerPlymouth Tube Co Intermediate Assembler or Fabricator
Rebar Size#18 Coupler ModelZap Screwlok SL
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)MM19104336 Rebar Heat Number(s)PL1120114301
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-02-09-23-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory02/19/2021fsaylor
No
10K Service Splice Info
2021-02-09-23-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory02/19/2021bewing
No
100 Cycle Service Splice Info
2021-02-09-23-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory02/19/2021fsaylor
No
Service Splice Info
2021-02-09-23-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory02/19/2021fsaylor
No
Service Splice Info

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-02-09-23-1 CTM 670-December 2013
DIME Test ID: 2021-02-09-23-2 CTM 670-December 2013
DIME Test ID: 2021-02-09-23-3 CTM 670-December 2013
DIME Test ID: 2021-02-09-23-4 CTM 670-December 2013