Sample Record
Owner Labs
- G3 Quality, Incorporated - Cerritos
- Granite Construction Company - Santa Paula
DIME Sample ID 2021-01-15-10
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 215108 DEA: 07337604 EFIS: 0717000036 |
---|---|
DIST-CO-RTE-PM | 07-LA-14-R28.9/R29.2 |
Award Date | 10/15/2020 |
Closeout Date | 05/04/2023 |
Work Description | REPLACE EXISTING STORM DRAIN, AND CONSTRUCT A COLLECTION SYSTEM. |
Location Description | LOS ANGELES COUNTY IN AND NEAR SANTA CLARITA FROM 0.8 MILE NORTH OF PLACERITA CANYON ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF GOLDEN VALLEY ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 02/24/2021) |
Sample Information
Sample Taken Date | 01/15/2021 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/18/2021 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 1-1/2"x3/4" |
The quantity of what the sample constitutes | 300 lbs | From where was the sample collected | Source |
First name of sampler or witnessed by | William | Last name of sampler or witnessed by | Lucas |
Title of sampler | Technician | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Construction - Big Rock | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0046::BIG ROCK CREEK- GRANITE |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2021-01-15-10-1 ASTM C88-5 (Verified)
DIME Test ID: 2021-01-15-10-2 CTM 227-December 2014 (Verified)
DIME Test ID: 2021-01-15-10-3 CTM 202-November 2011 (Verified)
DIME Test ID: 2021-01-15-10-4 CTM 211-May 2010 (Verified)