Sample Record

Owner Lab

  • Coreslab

DIME Sample ID 2021-01-18-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213750
DEA: 120K0224
EFIS: 1214000097
DIST-CO-RTE-PM12-ORA-5-14.5/17.1
Award Date03/05/2019
Closeout DateNot set
Work DescriptionSouth County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING
QA Service Level1 (Verified on 04/15/2019)

Sample Information

Sample Taken Date01/18/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/19/2021
Sample typeQuality Control A brief description of the sampleMix Design 312
The quantity of what the sample constitutes20 cy From where was the sample collectedJob Site
First name of sampler or witnessed byFrancisco Last name of sampler or witnessed byLopez
Title of samplerQ C Supervisor Telephone number of sampler
Laboratory sample identification008 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCoreslab Structures L A Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameOso Parkway Route 5

Material Information

Material TypeConcrete The concrete mix design number312
The truck number from where the sample was collectedTruck 2 Batch 4 5 6 The batch plant ticket number from where the sample was collected77246 77247 77248
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBed 9 from front discharge RMT into wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-01-18-4-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteBrandon Malott, Coreslab01/18/2021Brandon Malott
Yes
01/20/2021
2021-01-18-4-2ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of ConcreteFrancisco Lopez, Coreslab01/18/2021Brandon Malott
Yes
01/20/2021
2021-01-18-4-3ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure MethodFrancisco Lopez, Coreslab01/18/2021Brandon Malott
Yes
01/20/2021
2021-01-18-4-4ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensFrancisco Lopez, Coreslab01/19/2021Brandon Malott
Yes
01/20/2021
2021-01-18-4-5CTM 556-January 2018: Method of Test for Slump of Fresh Portland Cement ConcreteFrancisco Lopez, Coreslab01/18/2021Brandon Malott
Yes
01/20/2021VSI 1
2021-01-18-4-6CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)Francisco Lopez, Coreslab01/18/2021Brandon Malott
Yes
01/20/2021Both girders were max concrete temp of 131°F. and the chamber temp got to 115°F.

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-01-18-4-1 ASTM C1064-17 (Verified)
DIME Test ID: 2021-01-18-4-2 ASTM C138-17a (Verified)
DIME Test ID: 2021-01-18-4-3 ASTM C231-17a (Verified)
DIME Test ID: 2021-01-18-4-4 ASTM C39-17a (Verified)
DIME Test ID: 2021-01-18-4-5 CTM 556-January 2018 (Verified)
DIME Test ID: 2021-01-18-4-6 CTM TEMP1-16 (Verified)