Sample Record
Owner Lab
- CT D03 - Olivehurst Northern Regional Laboratory
DIME Sample ID 2020-05-13-37
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 213485 DEA: 032F9804 EFIS: 0312000026 |
---|---|
DIST-CO-RTE-PM | 03-COL-20-31.7/32.9 |
Award Date | 10/15/2018 |
Closeout Date | 05/11/2022 |
Work Description | PAVEMENT REHABILITATION |
Location Description | COLUSA COUNTY IN AND NEAR COLUSA FROM 0.1 MILE EAST OF THE MARKET STREET/STATE ROUTE 20 INTERSECTION TO 0.1 MILE SOUTH OF BUTTE VISTA DRIVE |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 05/13/2020 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2020 |
Sample type | Verification | A brief description of the sample | 1/2 inch HMA - A w/RAP |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brad | Last name of sampler or witnessed by | McKeenan |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | JMF20-020B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Teichert Hallwood | Transportation Laboratory (TL) Number | C778171 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-58-0006::HALLWOOD PLANT |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Cold Feed | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
JMF Information
Verification ID | JMF3513-2020-220 | Date Created | 11/19/2020 |
---|---|---|---|
JMF Submittal ID | JMF3511-23-2020-308 | JMF Status | Submittal Accepted for Verification |
Producer Mix ID | HD201706 | Authorized Date | N/A |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-05-13-37-1 AASHTO T335-09r13 (Verified)
DIME Test ID: 2020-05-13-37-2 AASHTO T96-02r10 (Verified)
DIME Test ID: 2020-05-13-37-3 AASHTO T176-08 (Verified)
DIME Test ID: 2020-05-13-37-4 AASHTO T304-11 (Verified)
DIME Test ID: 2020-05-13-37-5 ASTM D4791-10 (Verified)
DIME Test ID: 2020-05-13-37-6 CTM 204-June 2010 (Verified)
DIME Test ID: 2020-05-13-37-7 AASHTO T85-13 (Verified)
DIME Test ID: 2020-05-13-37-8 AASHTO T84-14 (Verified)
DIME Test ID: 2020-05-13-37-9 AASHTO T27-14 (Verified)
DIME Test ID: 2020-05-13-37-10 AASHTO T85-13 (Verified)