Sample Record
Owner Lab
- Trinity Engineering Laboratories, Incorporated - Fresno
DIME Sample ID 2014-02-20-8253112
Project Information
Project Identifiers | Project ID: 10016 DEA: 06342524 EFIS: 0600000381 |
---|---|
DIST-CO-RTE-PM | 06-FRE-180-R71.8/74.5 |
Award Date | 04/23/2013 |
Closeout Date | 10/19/2020 |
Work Description | NEW EXPRESS HIGHWAY |
Location Description | FRESNO COUNTY ABOUT 6.3 MILES EAST OF FRESNO FROM 0.6 MILE WEST OF QUALITY AVENUE TO 0.2 MILE WEST OF SMITH AVENUE |
QA Service Level | 1 (Verified on 07/23/2013) |
Sample Information
Sample Taken Date | 02/20/2014 | Sample Unique Key | 8253112 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/21/2014 |
Sample type | Quality Control | A brief description of the sample | Type II Cement |
The quantity of what the sample constitutes | 10 concrete cylinders | From where was the sample collected | Other |
First name of sampler or witnessed by | Joshua | Last name of sampler or witnessed by | Guilmette |
Title of sampler | QC Field Technician/Inspector | Telephone number of sampler | (559) 292-2188 |
Laboratory sample identification | 2014-02-20-08-25-01 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Mainline Bridge Deck East Bound | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Mainline Bridge Deck E/B | |
Structure name | Mainline Bridge Deck E/B |
Material Information
Material Type | Concrete | The concrete mix design number | ND14505 |
---|---|---|---|
The truck number from where the sample was collected | 9350 | The batch plant ticket number from where the sample was collected | 114104908 |
Concrete batch plant | 114 | The fabricator/manufacturer designation for the sample | Plant |
A detailed description of where the material sample was collected | Mainline Bridge Deck E/B | Where the material sample would have been placed if not sampled | Mainline Bridge Deck E/B |
From Lot No. | Not set | Bag Lot No. | Not set |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2014-02-20-8253112-1 ASTM C138-10b (Verified)
DIME Test ID: 2014-02-20-8253112-2 ASTM C143-10a (Verified)
DIME Test ID: 2014-02-20-8253112-3 ASTM C1064-08 (Verified)
DIME Test ID: 2014-02-20-8253112-4 ASTM C39-10 (Verified)
DIME Test ID: 2014-02-20-8253112-5 ASTM C39-10 (Verified)
DIME Test ID: 2014-02-20-8253112-6 ASTM C39-10 (Verified)
DIME Test ID: 2014-02-20-8253112-7 ASTM C39-10 (Verified)
DIME Test ID: 2014-02-20-8253112-8 ASTM C39-10 (Verified)