Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2020-11-10-9
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214832 DEA: 031J0804 EFIS: 0320000080 |
---|---|
DIST-CO-RTE-PM | 03-SAC-50-L0.01 |
Award Date | 11/13/2019 |
Closeout Date | 06/27/2022 |
Work Description | Repair bottom flanges of scraped girders,repair or replace lateral bracing elements and replace damaged sections of catwalk. Install vertical clearances gages on fenders as directed by USCG. |
Location Description | In Sacramento County in Sacramento on Route 50 at teh Sacramento RIver Viaduct(Pioneer) Bridges #24 0004L/R |
QA Service Level | 1 (Verified on 03/24/2020) |
Sample Information
Sample Taken Date | 11/10/2020 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/12/2020 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 110 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | Munoz |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Fontana Nucor TSI | Transportation Laboratory (TL) Number | C836611 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 7454 01 8755 01 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 390804A | |
Washer Mfg. Lot Number(s) | 0620 492 | Bolt Specification | A3125 A325 |
Bolt Length(s) | 2 | Nut Specification | A194 |
Washer Specification | F436 | Finish | F2329 |
Diameter/Size | .875 | Bolt Mfg. Lot Number | 757838 |
Rocap Test Requirement(s) | Lubricant Requirements(s) | Green |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2020-11-10-9-1 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2020-11-10-9-7 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-8 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-9 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-10 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-11 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-12 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-13 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-14 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-15 ASTM B499-14 (Verified)
DIME Test ID: 2020-11-10-9-16 ASTM E18-15 (Verified)
DIME Test ID: 2020-11-10-9-17 ASTM E18-15 (Verified)
DIME Test ID: 2020-11-10-9-18 ASTM E18-15 (Verified)
DIME Test ID: 2020-11-10-9-19 ASTM E18-15 (Verified)
DIME Test ID: 2020-11-10-9-20 ASTM F606-14a (Verified)