Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2020-11-11-2

Project Information

Project IdentifiersProject ID: 215129
DEA: 050N73U4
EFIS: 0520000166
DIST-CO-RTE-PM05-SB-101-7.3/9.6
Award Date10/22/2020
Closeout Date12/11/2023
Work Description!!Please CC Office Engineer Gabrielle Herrera on reports to RE and SR!! Segment 4C - Summerland: Construct HOV lanes and rehabilitation. Source inspection of sign structure trusses, lighting structures, steel soldier piles, epoxy coated rebar,
Location DescriptionSUMMERLAND FROM 0.2 MILES NORTH OF PARDARO LANE OVERCROSSING TO SAN YSIDRO CREEK BRIDGE
QA Service Level1 (Verified on 08/24/2020)

Sample Information

Sample Taken Date11/11/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing11/11/2020
Sample typeQuality Assurance A brief description of the sample#8 Bar HRC 120
The quantity of what the sample constitutes88 From where was the sample collectedSource
First name of sampler or witnessed byAndrew Last name of sampler or witnessed byWebster
Title of samplerQA Inspector Telephone number of sampler9254189838
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHeaded Reinforcement Corp, Fountain Valley, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB201-028-20 Structure unique identifier
Structure nameSummerland HOV lanes

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)3098549 Head Manufacturer Lot Number(s)100101704
Rebar Size#8 Headed Bar Model NameHRC 120
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Steel California
Head ManufacturerNucor Head FabricatorHeaded Reinforcement Corp
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2020-11-11-2-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/13/2020bewing
Yes
11/13/2020Ok Necking
2020-11-11-2-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/13/2020bewing
Yes
11/13/2020Ok Necking
2020-11-11-2-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/13/2020bewing
Yes
11/13/2020Ok Necking
2020-11-11-2-4ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/13/2020bewing
Yes
11/13/2020Ok Necking
2020-11-11-2-5ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/13/2020bewing
Yes
11/13/2020Ok Necking
2020-11-11-2-6ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory11/13/2020bewing
Yes
11/13/2020Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2020-11-11-2-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-11-11-2-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-11-11-2-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-11-11-2-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-11-11-2-5 ASTM A970-15e1 (Verified)
DIME Test ID: 2020-11-11-2-6 ASTM A970-15e1 (Verified)